How does electrical safety system work on ISS?












11












$begingroup$


Is there any possibility that the power consumption is greater than power supply on ISS? What happens (or potentially would happen) if we plug too many electric devices so that ISS couldn't handle it?



I believe that there is an emergency system which powers life control system when fuses are blown. Would astronauts then have to replace the fuses? If yes, how much time do they have for that?










share|improve this question









$endgroup$








  • 2




    $begingroup$
    Just wondering what country you are residing in -- many countries have switched over almost entirely to resettable breakers rather than fuses for commercial and residential buildings.
    $endgroup$
    – Carl Witthoft
    10 hours ago










  • $begingroup$
    @CarlWitthoft I'm from Poland, and now I'm quite convinced that this happened here too, but I was probably influenced by my experience with car fuses ;)
    $endgroup$
    – Elgirhath
    8 hours ago












  • $begingroup$
    @CarlWitthoft One of those countries is the UK - but I still refer to "fuses" and "the fusebox".
    $endgroup$
    – Martin Bonner
    8 hours ago
















11












$begingroup$


Is there any possibility that the power consumption is greater than power supply on ISS? What happens (or potentially would happen) if we plug too many electric devices so that ISS couldn't handle it?



I believe that there is an emergency system which powers life control system when fuses are blown. Would astronauts then have to replace the fuses? If yes, how much time do they have for that?










share|improve this question









$endgroup$








  • 2




    $begingroup$
    Just wondering what country you are residing in -- many countries have switched over almost entirely to resettable breakers rather than fuses for commercial and residential buildings.
    $endgroup$
    – Carl Witthoft
    10 hours ago










  • $begingroup$
    @CarlWitthoft I'm from Poland, and now I'm quite convinced that this happened here too, but I was probably influenced by my experience with car fuses ;)
    $endgroup$
    – Elgirhath
    8 hours ago












  • $begingroup$
    @CarlWitthoft One of those countries is the UK - but I still refer to "fuses" and "the fusebox".
    $endgroup$
    – Martin Bonner
    8 hours ago














11












11








11


1



$begingroup$


Is there any possibility that the power consumption is greater than power supply on ISS? What happens (or potentially would happen) if we plug too many electric devices so that ISS couldn't handle it?



I believe that there is an emergency system which powers life control system when fuses are blown. Would astronauts then have to replace the fuses? If yes, how much time do they have for that?










share|improve this question









$endgroup$




Is there any possibility that the power consumption is greater than power supply on ISS? What happens (or potentially would happen) if we plug too many electric devices so that ISS couldn't handle it?



I believe that there is an emergency system which powers life control system when fuses are blown. Would astronauts then have to replace the fuses? If yes, how much time do they have for that?







iss power electronics






share|improve this question













share|improve this question











share|improve this question




share|improve this question










asked 14 hours ago









ElgirhathElgirhath

685




685








  • 2




    $begingroup$
    Just wondering what country you are residing in -- many countries have switched over almost entirely to resettable breakers rather than fuses for commercial and residential buildings.
    $endgroup$
    – Carl Witthoft
    10 hours ago










  • $begingroup$
    @CarlWitthoft I'm from Poland, and now I'm quite convinced that this happened here too, but I was probably influenced by my experience with car fuses ;)
    $endgroup$
    – Elgirhath
    8 hours ago












  • $begingroup$
    @CarlWitthoft One of those countries is the UK - but I still refer to "fuses" and "the fusebox".
    $endgroup$
    – Martin Bonner
    8 hours ago














  • 2




    $begingroup$
    Just wondering what country you are residing in -- many countries have switched over almost entirely to resettable breakers rather than fuses for commercial and residential buildings.
    $endgroup$
    – Carl Witthoft
    10 hours ago










  • $begingroup$
    @CarlWitthoft I'm from Poland, and now I'm quite convinced that this happened here too, but I was probably influenced by my experience with car fuses ;)
    $endgroup$
    – Elgirhath
    8 hours ago












  • $begingroup$
    @CarlWitthoft One of those countries is the UK - but I still refer to "fuses" and "the fusebox".
    $endgroup$
    – Martin Bonner
    8 hours ago








2




2




$begingroup$
Just wondering what country you are residing in -- many countries have switched over almost entirely to resettable breakers rather than fuses for commercial and residential buildings.
$endgroup$
– Carl Witthoft
10 hours ago




$begingroup$
Just wondering what country you are residing in -- many countries have switched over almost entirely to resettable breakers rather than fuses for commercial and residential buildings.
$endgroup$
– Carl Witthoft
10 hours ago












$begingroup$
@CarlWitthoft I'm from Poland, and now I'm quite convinced that this happened here too, but I was probably influenced by my experience with car fuses ;)
$endgroup$
– Elgirhath
8 hours ago






$begingroup$
@CarlWitthoft I'm from Poland, and now I'm quite convinced that this happened here too, but I was probably influenced by my experience with car fuses ;)
$endgroup$
– Elgirhath
8 hours ago














$begingroup$
@CarlWitthoft One of those countries is the UK - but I still refer to "fuses" and "the fusebox".
$endgroup$
– Martin Bonner
8 hours ago




$begingroup$
@CarlWitthoft One of those countries is the UK - but I still refer to "fuses" and "the fusebox".
$endgroup$
– Martin Bonner
8 hours ago










1 Answer
1






active

oldest

votes


















17












$begingroup$

This answer addresses only the US side of the ISS.



Like everything else on the ISS, it's complicated.



enter image description here



Fuses are not commonly used on the ISS. There are fuses within the battery subassemblies, to protect against internal battery shorts.



The common circuit protection device on the ISS is the Remote Power Controller (RPC), a commandable "smart circuit breaker". An RPC monitors the current passing through it and opens the circuit if the current exceeds a limit for a specified amount of time. The RPC can be commanded to reset once the problem has been resolved. The RPCs are grouped into RPC Modules (RPCMs). If the input voltage to an RPCM drops too low, all the RPCs in the RPCM will open.



If the power usage gets higher than the supplied power can handle (for example, if a solar array is lost), the onboard computers (MDMs) can command a 'load shed'. Using tables preloaded into the software, the MDM(s) controlling the electrical power system will command the RPCs on a set of devices open, powering them off.



If the power loss event is predicted, the flight controllers can most likely do a better job of powering down the station based on the current configuration than the load shed tables would. They would send commands to open the desired RPCs.



enter image description here




I believe that there is an emergency system which powers life control system when fuses are blown.




As stated, fuses are not commonly used, and there is no such emergency system. The ISS already runs off battery power when the solar arrays are not generating power. The load shed tables are built so that critical functions are the last to be turned off.



Acronymology:




  • ARCU - American / Russian Conversion Unit

  • BCDU - Battery Charge / Discharge Unit


  • BGA - Beta Gimbal Assembly


  • DDCU - DC / DC Converter Unit

  • ECU - Electrical Control Unit

  • IDA - Integrated Distribution Assembly

  • IEA - Integrated Electronics Assembly

  • MDM - Multiplexer / Demultiplexer (an absolutely awful name for an
    onboard computer)

  • PFCS - Pump / Flow Control System

  • PVA - Photovoltaic Array

  • PVR - Photovoltaic Radiator

  • RPDA - Remote Power Distribution Assembly

  • SPDA - Secondary Power Distribution Assembly

  • SSU - Sequential Shunt Unit

  • Z1 - the name of a centrally located ISS truss unit


Source - personal notes. NASA does not provide a good reference source for the ISS. There is some information in this paper, from which the images are taken.






share|improve this answer











$endgroup$













    Your Answer





    StackExchange.ifUsing("editor", function () {
    return StackExchange.using("mathjaxEditing", function () {
    StackExchange.MarkdownEditor.creationCallbacks.add(function (editor, postfix) {
    StackExchange.mathjaxEditing.prepareWmdForMathJax(editor, postfix, [["$", "$"], ["\\(","\\)"]]);
    });
    });
    }, "mathjax-editing");

    StackExchange.ready(function() {
    var channelOptions = {
    tags: "".split(" "),
    id: "508"
    };
    initTagRenderer("".split(" "), "".split(" "), channelOptions);

    StackExchange.using("externalEditor", function() {
    // Have to fire editor after snippets, if snippets enabled
    if (StackExchange.settings.snippets.snippetsEnabled) {
    StackExchange.using("snippets", function() {
    createEditor();
    });
    }
    else {
    createEditor();
    }
    });

    function createEditor() {
    StackExchange.prepareEditor({
    heartbeatType: 'answer',
    autoActivateHeartbeat: false,
    convertImagesToLinks: false,
    noModals: true,
    showLowRepImageUploadWarning: true,
    reputationToPostImages: null,
    bindNavPrevention: true,
    postfix: "",
    imageUploader: {
    brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
    contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/3.0/"u003ecc by-sa 3.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
    allowUrls: true
    },
    noCode: true, onDemand: true,
    discardSelector: ".discard-answer"
    ,immediatelyShowMarkdownHelp:true
    });


    }
    });














    draft saved

    draft discarded


















    StackExchange.ready(
    function () {
    StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fspace.stackexchange.com%2fquestions%2f34966%2fhow-does-electrical-safety-system-work-on-iss%23new-answer', 'question_page');
    }
    );

    Post as a guest















    Required, but never shown

























    1 Answer
    1






    active

    oldest

    votes








    1 Answer
    1






    active

    oldest

    votes









    active

    oldest

    votes






    active

    oldest

    votes









    17












    $begingroup$

    This answer addresses only the US side of the ISS.



    Like everything else on the ISS, it's complicated.



    enter image description here



    Fuses are not commonly used on the ISS. There are fuses within the battery subassemblies, to protect against internal battery shorts.



    The common circuit protection device on the ISS is the Remote Power Controller (RPC), a commandable "smart circuit breaker". An RPC monitors the current passing through it and opens the circuit if the current exceeds a limit for a specified amount of time. The RPC can be commanded to reset once the problem has been resolved. The RPCs are grouped into RPC Modules (RPCMs). If the input voltage to an RPCM drops too low, all the RPCs in the RPCM will open.



    If the power usage gets higher than the supplied power can handle (for example, if a solar array is lost), the onboard computers (MDMs) can command a 'load shed'. Using tables preloaded into the software, the MDM(s) controlling the electrical power system will command the RPCs on a set of devices open, powering them off.



    If the power loss event is predicted, the flight controllers can most likely do a better job of powering down the station based on the current configuration than the load shed tables would. They would send commands to open the desired RPCs.



    enter image description here




    I believe that there is an emergency system which powers life control system when fuses are blown.




    As stated, fuses are not commonly used, and there is no such emergency system. The ISS already runs off battery power when the solar arrays are not generating power. The load shed tables are built so that critical functions are the last to be turned off.



    Acronymology:




    • ARCU - American / Russian Conversion Unit

    • BCDU - Battery Charge / Discharge Unit


    • BGA - Beta Gimbal Assembly


    • DDCU - DC / DC Converter Unit

    • ECU - Electrical Control Unit

    • IDA - Integrated Distribution Assembly

    • IEA - Integrated Electronics Assembly

    • MDM - Multiplexer / Demultiplexer (an absolutely awful name for an
      onboard computer)

    • PFCS - Pump / Flow Control System

    • PVA - Photovoltaic Array

    • PVR - Photovoltaic Radiator

    • RPDA - Remote Power Distribution Assembly

    • SPDA - Secondary Power Distribution Assembly

    • SSU - Sequential Shunt Unit

    • Z1 - the name of a centrally located ISS truss unit


    Source - personal notes. NASA does not provide a good reference source for the ISS. There is some information in this paper, from which the images are taken.






    share|improve this answer











    $endgroup$


















      17












      $begingroup$

      This answer addresses only the US side of the ISS.



      Like everything else on the ISS, it's complicated.



      enter image description here



      Fuses are not commonly used on the ISS. There are fuses within the battery subassemblies, to protect against internal battery shorts.



      The common circuit protection device on the ISS is the Remote Power Controller (RPC), a commandable "smart circuit breaker". An RPC monitors the current passing through it and opens the circuit if the current exceeds a limit for a specified amount of time. The RPC can be commanded to reset once the problem has been resolved. The RPCs are grouped into RPC Modules (RPCMs). If the input voltage to an RPCM drops too low, all the RPCs in the RPCM will open.



      If the power usage gets higher than the supplied power can handle (for example, if a solar array is lost), the onboard computers (MDMs) can command a 'load shed'. Using tables preloaded into the software, the MDM(s) controlling the electrical power system will command the RPCs on a set of devices open, powering them off.



      If the power loss event is predicted, the flight controllers can most likely do a better job of powering down the station based on the current configuration than the load shed tables would. They would send commands to open the desired RPCs.



      enter image description here




      I believe that there is an emergency system which powers life control system when fuses are blown.




      As stated, fuses are not commonly used, and there is no such emergency system. The ISS already runs off battery power when the solar arrays are not generating power. The load shed tables are built so that critical functions are the last to be turned off.



      Acronymology:




      • ARCU - American / Russian Conversion Unit

      • BCDU - Battery Charge / Discharge Unit


      • BGA - Beta Gimbal Assembly


      • DDCU - DC / DC Converter Unit

      • ECU - Electrical Control Unit

      • IDA - Integrated Distribution Assembly

      • IEA - Integrated Electronics Assembly

      • MDM - Multiplexer / Demultiplexer (an absolutely awful name for an
        onboard computer)

      • PFCS - Pump / Flow Control System

      • PVA - Photovoltaic Array

      • PVR - Photovoltaic Radiator

      • RPDA - Remote Power Distribution Assembly

      • SPDA - Secondary Power Distribution Assembly

      • SSU - Sequential Shunt Unit

      • Z1 - the name of a centrally located ISS truss unit


      Source - personal notes. NASA does not provide a good reference source for the ISS. There is some information in this paper, from which the images are taken.






      share|improve this answer











      $endgroup$
















        17












        17








        17





        $begingroup$

        This answer addresses only the US side of the ISS.



        Like everything else on the ISS, it's complicated.



        enter image description here



        Fuses are not commonly used on the ISS. There are fuses within the battery subassemblies, to protect against internal battery shorts.



        The common circuit protection device on the ISS is the Remote Power Controller (RPC), a commandable "smart circuit breaker". An RPC monitors the current passing through it and opens the circuit if the current exceeds a limit for a specified amount of time. The RPC can be commanded to reset once the problem has been resolved. The RPCs are grouped into RPC Modules (RPCMs). If the input voltage to an RPCM drops too low, all the RPCs in the RPCM will open.



        If the power usage gets higher than the supplied power can handle (for example, if a solar array is lost), the onboard computers (MDMs) can command a 'load shed'. Using tables preloaded into the software, the MDM(s) controlling the electrical power system will command the RPCs on a set of devices open, powering them off.



        If the power loss event is predicted, the flight controllers can most likely do a better job of powering down the station based on the current configuration than the load shed tables would. They would send commands to open the desired RPCs.



        enter image description here




        I believe that there is an emergency system which powers life control system when fuses are blown.




        As stated, fuses are not commonly used, and there is no such emergency system. The ISS already runs off battery power when the solar arrays are not generating power. The load shed tables are built so that critical functions are the last to be turned off.



        Acronymology:




        • ARCU - American / Russian Conversion Unit

        • BCDU - Battery Charge / Discharge Unit


        • BGA - Beta Gimbal Assembly


        • DDCU - DC / DC Converter Unit

        • ECU - Electrical Control Unit

        • IDA - Integrated Distribution Assembly

        • IEA - Integrated Electronics Assembly

        • MDM - Multiplexer / Demultiplexer (an absolutely awful name for an
          onboard computer)

        • PFCS - Pump / Flow Control System

        • PVA - Photovoltaic Array

        • PVR - Photovoltaic Radiator

        • RPDA - Remote Power Distribution Assembly

        • SPDA - Secondary Power Distribution Assembly

        • SSU - Sequential Shunt Unit

        • Z1 - the name of a centrally located ISS truss unit


        Source - personal notes. NASA does not provide a good reference source for the ISS. There is some information in this paper, from which the images are taken.






        share|improve this answer











        $endgroup$



        This answer addresses only the US side of the ISS.



        Like everything else on the ISS, it's complicated.



        enter image description here



        Fuses are not commonly used on the ISS. There are fuses within the battery subassemblies, to protect against internal battery shorts.



        The common circuit protection device on the ISS is the Remote Power Controller (RPC), a commandable "smart circuit breaker". An RPC monitors the current passing through it and opens the circuit if the current exceeds a limit for a specified amount of time. The RPC can be commanded to reset once the problem has been resolved. The RPCs are grouped into RPC Modules (RPCMs). If the input voltage to an RPCM drops too low, all the RPCs in the RPCM will open.



        If the power usage gets higher than the supplied power can handle (for example, if a solar array is lost), the onboard computers (MDMs) can command a 'load shed'. Using tables preloaded into the software, the MDM(s) controlling the electrical power system will command the RPCs on a set of devices open, powering them off.



        If the power loss event is predicted, the flight controllers can most likely do a better job of powering down the station based on the current configuration than the load shed tables would. They would send commands to open the desired RPCs.



        enter image description here




        I believe that there is an emergency system which powers life control system when fuses are blown.




        As stated, fuses are not commonly used, and there is no such emergency system. The ISS already runs off battery power when the solar arrays are not generating power. The load shed tables are built so that critical functions are the last to be turned off.



        Acronymology:




        • ARCU - American / Russian Conversion Unit

        • BCDU - Battery Charge / Discharge Unit


        • BGA - Beta Gimbal Assembly


        • DDCU - DC / DC Converter Unit

        • ECU - Electrical Control Unit

        • IDA - Integrated Distribution Assembly

        • IEA - Integrated Electronics Assembly

        • MDM - Multiplexer / Demultiplexer (an absolutely awful name for an
          onboard computer)

        • PFCS - Pump / Flow Control System

        • PVA - Photovoltaic Array

        • PVR - Photovoltaic Radiator

        • RPDA - Remote Power Distribution Assembly

        • SPDA - Secondary Power Distribution Assembly

        • SSU - Sequential Shunt Unit

        • Z1 - the name of a centrally located ISS truss unit


        Source - personal notes. NASA does not provide a good reference source for the ISS. There is some information in this paper, from which the images are taken.







        share|improve this answer














        share|improve this answer



        share|improve this answer








        edited 5 hours ago

























        answered 13 hours ago









        Organic MarbleOrganic Marble

        59.2k3163254




        59.2k3163254






























            draft saved

            draft discarded




















































            Thanks for contributing an answer to Space Exploration Stack Exchange!


            • Please be sure to answer the question. Provide details and share your research!

            But avoid



            • Asking for help, clarification, or responding to other answers.

            • Making statements based on opinion; back them up with references or personal experience.


            Use MathJax to format equations. MathJax reference.


            To learn more, see our tips on writing great answers.




            draft saved


            draft discarded














            StackExchange.ready(
            function () {
            StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fspace.stackexchange.com%2fquestions%2f34966%2fhow-does-electrical-safety-system-work-on-iss%23new-answer', 'question_page');
            }
            );

            Post as a guest















            Required, but never shown





















































            Required, but never shown














            Required, but never shown












            Required, but never shown







            Required, but never shown

































            Required, but never shown














            Required, but never shown












            Required, but never shown







            Required, but never shown







            Popular posts from this blog

            How to make a Squid Proxy server?

            Is this a new Fibonacci Identity?

            19世紀